SOFC
HELP design
HELP applications
Appendix
Fuel Cells in General
SOFC's in General
| 
| 
Example Calculation of Payback Time
Data: |
|
|
SOFC type: |
SOFC-HELP |
|
Power-electrical |
100 |
Watt electrical |
Efficiency-electrical |
48 |
% |
Power-thermal |
108 |
Watt thermal |
Total Fuel Cell System Investment |
900 |
|
Gas price in NL |
0,05 |
EUR/kWh(thermal) |
Electricity price in NL |
0,19 |
EUR/kWh(electrical) |
|
|
|
Thermal efficiency of conventional combustion |
85 |
% |
|
|
|
Calculations: |
|
|
|
kWh/year |
EUR/year |
Electrical yield |
876 |
166 |
Thermal |
949 |
47 |
Total SOFC yield |
|
214 |
|
|
|
Gas feed cost |
1825 |
91 |
Thermal conversion of conventional combustion |
1551 |
77 |
|
|
|
Profit in EUR/year |
|
123 |
Profit in EUR/year compared to combustion |
|
136 |
|
|
|
Pay back time in years |
|
7,3 |
Payback time in years compared to combustion |
|
6,6 |
Conclusion: Profitable, while the payback time is well within the expected life time of >10 years. |